Inspected by John Smith
1 Adelaide Street Brisbane
Report
Building Inspection
Date
Feb 25, 2021
Client
James Winton

This report Complies with Australian Standard AS 4349.1-2007 Inspection of Buildings Part 1: Pre-Purchase Inspections of Residential Buildings - Appendix Summary

Overview

Safety Hazards
1 Safety Hazard requires action 
Major Defects
1 Major Defect requires action
Minor Maintenance
4 Minor Defects require action

Please refer to the report for explanations.

Photos

Description

Type of Building
Residential House
Style of Building
Conventional single storey
Number of Stories
Single Storey
Age of Building
3-5 years old
Roof Covering
Colour Bond Sheeting
Roof Frame
Hardwood Roof Trusses
Wall Construction
Weather Board Walls
Floor Construction
Concrete Slab on Ground
Internal Wall Construction
Timber Framed Walls
Building tenancy
Occupied
Building furnished
Yes
Front of Building Faces
East
Hot water unit
External free standing gas HWU
Solar
Electrical solar panels present
Airconditioning
Split system
Mains (Submains) Power board
2 x RCD's
Smoke Alarms
Hard wired smoke alarms

Kitchen

Access Limitations
No limitations

Floor

Response
Drummy tiles
Comments
Gaps in timber flooring
Defect Significance
Minor
Defect Type
A (Damage)

Ceiling

No defects

Walls

No defects

Sink

No defects

Taps

No defects

Splashback

No defects

Bench top

No defects

Top Cupboards

No defects

Bottom Cupboards

No defects

Food Cupboards

No defects

Window/s

No defects

Lounge Room

Access Limitations
No limitations

Ceiling

No defects

Walls

No defects

Floor

No defects

Doors and door furniture

No defects

Front Door and door furniture

No defects

Window/s

No defects

Dining Room

Access Limitations
Furniture
Clutter

Ceiling

No defects

Walls

No defects

Floor

No defects

Window/s

No defects

Rear Exit Door

No defects

Skirting

No defects

Architraves

No defects

Front Entrance Area

Access Limitations
No limitations

Ceiling

No defects

Walls

No defects

Floor

No defects

Front Door and door furniture

No defects

Passageway to Bedrooms

Access Limitations
No limitations

Floor

Response
Other
Comments
Timber floor boards damaged
Defect Significance
Minor
Defect Type
A (Damage)

Ceiling

No defects

Walls

No defects

Bedroom 1

Access Limitations
No limitations

Ceiling

No defects

Walls

No defects

Floor

No defects

Window/s

No defects

Door/s and door furniture

No defects

Skirting

No defects

Architraves

No defects

Robe

No defects

Bedroom 2

Access Limitations
No limitations

Door/s and door furniture

Response
Other
Comments
Damaged plantation shutters
Defect Significance
Safety Hazard
Defect Type
A (Damage)

Ceiling

No defects

Walls

No defects

Floor

No defects

Window/s

No defects

Rear Exit Door/s

No defects

Skirting

No defects

Architraves

No defects

Robe

No defects

Main Bathroom

Access Limitations
No limitations

Walls

Response
Other
Defect Significance
Minor
Defect Type
B (Distortion, Warping, Twisting)

Ceiling

No defects

Wall Tiles

No defects

Shower Wall Tiles

No defects

Shower floor

No defects

Shower Screen

No defects

Bathroom floor

No defects

Basins

No defects

Splashback Tiles

No defects

Taps

No defects

Mirror

No defects

Vanity Cupboard

No defects

Bath

No defects

Bath Splashback

No defects

Bath Side Tiles

No defects

Pan and cistern

No defects

Door and door furniture

No defects

Window/s

No defects

Architraves

No defects

Skirting tiles

No defects

Garage

Access Limitations
No limitations

Rear roller door

Response
Door damaged suggest maintenance
Defect Significance
Major
Defect Type
B (Distortion, Warping, Twisting)

Ceiling

No defects

Walls

No defects

Concrete Floor

No defects

Window/s

No defects

Entrance Doors

No defects

Side entrance door

No defects

Rear Exit Door/s

No defects

Internal Access Door

No defects

Exterior

Access Limitations
No limitations

Exterior cladding/finish

No defects

Windows

No defects

Windows

No defects

Window sills

No defects

Doors

No defects

Doors

No defects

Door sills

No defects

Chimney/Flue

No defects

Weep holes

No defects

Sub Floor

Access Limitations
Clutter
Areas of Subfloor NOT inspected
Front and rear landings. No access available.

Flooring

No defects

Ventilation

No defects

Sub floor door

No defects

Piers

No defects

Roof Exterior

Access Limitations
No limitations

Gutters

Response
Holding water in some areas
Defect Significance
Minor
Defect Type
B (Distortion, Warping, Twisting)

Roof Covering

No defects

Ridges

No defects

Downpipes

No defects

Valleys

No defects

Eaves

No defects

Fascia

No defects

Bargeboard

No defects

Lead flashings

No defects

Building: Report summary

Incidence of Major Defects compared to similar buildings

Low

Incidence of Minor Defects compared to similar buildings

Typical

Overall condition summary

Above Average

Overall Summary

Weather conditions at the time of the inspection

Dry

Recent weather conditions

Dry

The areas inspected were

The Building Interior
The Building Exterior
The Roof Exterior

Therefore, the areas or section that access should be fully gained

The Roof Void Space
Garden Shed

Compared to other buildings of the same age and construction, the condition of this building appears to be

Above Average

The areas in which visual inspection was obstructed

The Roof Void Space
Garden Shed

The areas NOT accessible for any inspection were

The Roof Void Space
Garden Shed

Timber Pest Inspection

No active termites (live specimens) evident on the day of inspection

Further Inspections Recommended

Pest (termite) inspection

Terms & Conditions

Part 1: Purpose and Scope of Inspection

This report complies with Australian Standard AS4349.1 - 2007 Inspection of Buildings, Part 1: Pre Purchase Inspections - Residential Buildings.

Inspection Agreement - Individual title property

Requirement for Inspection agreement AS 4349.1 - 2007 requires that an inspection agreement be entered into between the inspector & the client prior to the conduct of the inspection. This agreement sets out specific limitations on the scope of the inspection and on limits that apply in carrying it out. Where specific State or Territory requirements apply in addition to the scope of work in this agreement, or where the inspector and client agree to additional matters being covered, that additional scope is listed at the end of this agreement. It is assumed that the existing use of the building will continue.

Purpose of Inspection

The purpose of the inspection is to provide advice to a prospective purchaser or other interested party regarding the condition of the property on the date and at the time of the inspection. The advice is limited to the reporting of the condition of the Building Elements in accord with Appendix B or C AS4349.1-2007 (Appendix B for Strata or Company Title and Appendix C for other residential buildings).

Important Information and Disclaimer

Any person who relies upon the contents of this report does so acknowledging that the following clauses both below and at the end of this report. These define the Scope and Limitations of the inspection and form an integral part of the report. Before you decide to purchase this property you should read and understand all of the information contained herein. It will help explain what is involved in a Residential Pre-Purchase Building Inspection Report, the difficulties faced by an inspector and why it is not possible to guarantee that a property is free of defects, latent or otherwise. This information forms an integral part of the report. If there is anything contained within this report that is not clear or you have difficulty understanding, please contact the inspector prior to acting on this report.

The extent and thoroughness of this inspection has been limited by our reading of what was reasonable by way of time, intrusion and risk of doing physical damage to the property being inspected. We have not inspected woodwork or other parts of the structure which are covered, unexposed or inaccessible and we are therefore unable to report that any such part of the structure is free from defect. Identification of hazardous materials or situations that may be in the building or on or near the property is outside the scope of this inspection. This report is not a certificate of compliance of the property within the requirements of any Act, regulation, ordinance, local law or by-law, and is not a warranty against problems developing with the building in the future. This report does not include the identification of unauthorised building work or of work not compliant with building regulations. With respect to minor defects, the inspection is limited to reporting on their overall extent. It is not intended to detail each and every individual minor defect or imperfection. This service is provided on an independent professional basis. It seeks to present a factual, unbiased and balanced assessment. We have no financial interest in any work that may be recommended or in any share of commission if the property is sold.

Scope of Inspection

The inspection comprised a visual assessment of the property to identify major defects and safety hazards, and to form an opinion regarding the general condition of the property at the time of inspection. An estimate of the cost of rectification of defects is outside the scope of the Standard and therefore does not form part of this report.

AS 4349.1 - 2007 requires that the basis for comparison is a building of similar age and similar type to the subject building and which is in reasonable condition, having been adequately maintained over the life of the building. This means that building being inspected may not comply with Australian Standards, building regulations or specific state or territory requirements applicable at the time of the inspection.

What is reported on:

  • The inspection includes subjective appraisal by an inspector competent to assess the condition of residential buildings. It involves a subjective assessment so different inspectors or even the same inspector on a different occasion may reach different conclusions
  • The inspection comprises a visual assessment of the property to identify major defects and to form an opinion regarding the general condition of the property at the time of inspection.
  • The following areas shall be inspected where applicable: 
    • The interior of the building: ceilings; walls; floors; windows; doors & frames; kitchen; bathroom; WC; ensuite; laundry; stairs & damp problems 
    • The exterior of the building: walls (including lintels, claddings, doors & windows); timber or steel frames & structures; chimneys; stairs; balconies, verandas, patios, decks, suspended concrete floors, balustrades 
    • The roof exterior: roof (including tiles, shingles & slates, roof sheeting, gables, flashings); skylights, vents, flues; valleys; guttering; downpipes; eaves, fascias and barges 
    • The roof space: roof covering; roof framing; sarking; party walls; insulation 
    • The sub-floor space: timber floor (including supports, floor, ventilation, drainage, damp); suspended concrete floors 
    • The property within 30m of the house and within the boundaries of the site: car accommodation, detached laundry, ablution facilities and garden sheds; retaining walls (where supporting other structures and landscaping retaining walls > 700mm high); paths & driveways; steps ; fencing (excluding swimming pool fences) ; surface water (drainage effectiveness)

What is not reported on:

  • general exclusions detailed in the standard AS 4349.1 - 2007 
  • Parts of a building that are under construction 
  • The inspection is not intended to include rigorous assessment of all building elements in a property 
  • Defects that would only be apparent under particular weather conditions or when using particular fittings & fixtures 
  • Defects not apparent due to occupancy or occupancy behavior eg non use of a leaking shower 
  • The inspection report is not a certificate of compliance of the property within the requirements of any Act, regulation, ordinance, local law or by-law and is not a warranty against problems developing with the building in the future 
  • Unauthorized building work or of work not compliant with building regulations
  • Title and ownership matters, matters concerning easements, covenants, restrictions, zoning certificates and all other law-related matters 
  • Estimation of the cost of rectification of specific defects.
  • Specifics excluded by the standard AS 4349.1 - 2007 Footings below ground, concealed damp-proof course, electrical installations, operation of smoke detectors, light switches and fittings, TV, sound and communication and security systems, concealed plumbing, adequacy of roof drainage as installed, gas fittings and fixtures, air conditioning, automatic garage door mechanisms, swimming pools and associated filtration and similar equipment, the operation of fireplaces and solid fuel heaters, including chimneys and flues, alarm systems, intercom systems, soft floor coverings, electrical appliances including dishwashers, incinerators, ovens, ducted vacuum systems, paint coatings except external protective coatings, health hazards e.g., allergies, soil toxicity, lead content, radon, presence of asbestos or urea formaldehyde), timber and metal framing sizes and adequacy, concealed tie downs and bracing, timber pest activity, other mechanical or electrical equipment (such as gates, inclinators), soil conditions, control joints, sustainable development provisions, concealed framing-timbers or any areas concealed by wall linings or sidings, landscaping, rubbish, floor cover, furniture and accessories, stored items, insulation, environmental matters e.g. BASIX, water tanks, BCA environmental provisions, energy efficiency, lighting efficiency.

 

Special Requirements

It is acknowledged that there are no special requirements placed on this inspection that are outside the scope of the abovementioned Australian Standard.

Limitations

This report is limited to a visual inspection of areas where safe and reasonable access is available and access permitted on the date and at the time of inspection. The Inspection will be carried out in accordance with AS4349.1-2007. The purpose of the inspection is to provide advice to a prospective purchaser regarding the condition of the property at the date and time of inspection. Areas for Inspection shall cover all safe and accessible areas. It does not purport to be geological as to foundation integrity or soil conditions, engineering as to structural, nor does it cover the condition of electrical, plumbing, gas or motorised appliances. It is strongly recommended that an appropriately qualified contractor check these services prior to purchase.

As a matter of course, and in the interests of safety, all prospective purchasers should have an electrical report carried out by a suitably qualified contractor.

This report is limited to (unless otherwise noted) the main structure on the site and any other building, structure or outbuilding within 30m of the main structure and within the site boundaries including fences.

Safe and Reasonable Access

Only areas to which safe and reasonable access is available were inspected. The Australian Standard 4349.1 defines reasonable access as "areas where safe, unobstructed access is provided and the minimum clearances specified below are available, or where these clearances are not available, areas within the inspector's unobstructed line of sight and within arm's length. Reasonable access does not include removing screws and bolts to access covers." Reasonable access does not include the use of destructive or invasive inspection methods nor does it include cutting or making access traps or moving heavy furniture, floor coverings or stored goods.

Dimensions for Reasonable Access

Roof Interior - Access opening = 400 x 500 mm - Crawl Space = 600 x 600mm - Height accessible from a 3.6m ladder.

Roof Exterior - Must be accessible from a 3.6m ladder placed on the ground.

Definitions


High: The frequency and/or magnitude of defects are beyond the inspector's expectations when compared to similar buildings of approximately the same age that have been reasonably well maintained.

Typical: The frequency and/or magnitude of defects are consistent with the inspector's expectations when compared to similar buildings of approximately the same age that have been reasonably well maintained.

Low: The frequency and/or magnitude of defects are lower than the inspector's expectations when compared to similar buildings of approximately the same age that have been reasonably well maintained.

Above Average: The overall condition is above that consistent with dwellings of approximately the same age and construction. Most items and areas are well maintained and show a reasonable standard of workmanship when compared with buildings of similar age and construction.

Average: The overall condition is consistent with dwellings of approximately the same age and construction. There will be areas or items requiring some repair or maintenance.

Below Average: The Building and its parts show some significant defects and/or poor non-tradesman like workmanship and/or long term neglect and/or defects requiring major repairs or reconstruction of major building elements.

Major Defect: Is a Defect requiring building works to avoid unsafe conditions, loss of function or further worsening of the defective item.

Minor Defect: Any Defect other than what is described as a major defect.

Structural Element: Physically distinguishable part of a structure. Note: for example, wall columns, beam, commection.

Accessible area: is any area of the property and structures allowing the inspector safe and reasonable access within the scope of the inspection.

 

The Definitions below apply to the TYPES OF DEFECTS associated with individual items/parts or inspection areas.

Damage: The buiulding material or item has deteriorated or is not fit for its designed purpose.

Distortion, Warping, Twisting: The item has moved out of shape or moved from its position.

Water Pentration, Dampness: Moisture has gained access to unplanned and/or unacceptable areas.

Material Deterioration: The item is subject to one or more of the following defects, rusting, rotting, corrision, decay.

Operational: The item or part does not function as expected.

Installation: The installation of an item is unacceptable, has failed or is absent.